Elitech LD-100 Refrigerant Leak Detector CFCs HCFCs HFCs Freon Gas Leak Sniffer Semi-conductor detector With Long Probe

Description: Elitech LD-100 Refrigerant Leak Detector offers great sensitivity and fastest response. This is achieved through the employment of a high sensitive...

  • Brand: Elitech
  • Product Code: LD-100
  • Availability: In Stock

Price: $99.99 $89.9910% off

Description

Elitech LD-100 Refrigerant Leak Detector offers great sensitivity and fastest response. This is achieved through the employment of a high sensitive semi-conductive sensor combined with a sophisticated microprocessor-controlled circuit. In addition to the supreme performance and functional advantages, it offers an uniquely designed shape to provide greater ease of use and comfort.


Main Features

• Sensor type: Semi-conductive sensor

• Minimum Sensitivity: 3g/yr

• Response time: <3s    

• Warm up time: <60s

 Ambient Environment: Temperature: 0℃~50℃; Humidity: < 80%RH(non condensing)

• Display method: Highlight LED display

 One-touch reset and six-level adjustable sensitivity

 True mechanical pump provides instant response and clearing

• Battery level indication

• Sensor failure indication

• Three 1.5V AA high-energy battery

• Unique shape design

• Flexible stainless probe



Application of refrigerant:

It will respond to all halogenated (including Chlorine of Fluorine) refrigerants. This includes, but is not limited to:

CFCs                    e.g.R12,R11,R500,R503 etc…

HCFCs                  e.g.R22,R123,R124,R502 etc…

HFCs                    e.g.R134a,R404a,R410A,R407C etc…

CH                        R600a


Package: 

1*Elitech LD100 with plastic box

1* Manual


Maintenance:

Proper maintenance is important and may extend the service life and improve the performance of your detector.

Warning: Turn the power off before clearing the shell of sensor.

Keep the sensor tip clean: Use cotton cloth or dry air to clean the shield on the sensor tip if it gets contaminated. If the sensor tip itself is contaminated, soak the tip in absolute alcohol for a few minutes, and then use compressed air to blow it dry, or dry it with cloth.

Note: Never use strong solvents such as Gasoline, mineral oil, turpentine, these solvents may coat the sensor with a thin film and reduce the sensitivity of the detector and make the detector slow to respond to a leak.

Put the detector and the sensor in a dry and clean place; Remove the batteries if the detector is not used for a long time.


Instruction: 

To download the manual, please click here.

Instruction video - How to Use Elitech LD-100 Refrigerant Halogen Leak Detector


Battery installation:

Open the battery cover, then install the batteries to the battery compartment of leak detector. Please pay attention to the direction during installation.

 



Write a review

Note: HTML is not translated!
    Bad           Good